Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 17, 2020, 06:25 AM
  • 18 0671_18 0670_12162020_223306.mp4

Date
12/16/2020
W/O
860087
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00696
PipeID
P14520
Time
10:25 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8288
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_860087_TV18081_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0670
Downstream MH
18 0671
Dir. of Survey
Upstream
Length Surveyed
166.2 ft.
Total Length
166.2 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
96
O&M Index
2
O&M Quick
2E00
O&M Rating
64
Overall Index
3
Overall Quick
Overall Rating
160
Pipe schematic from manhole 18 0670 to 18 0671
MH: 18 0670MH: 18 0671upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 06711.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish1.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish159.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start164.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start166.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0670166.2 ft. MWL - Water Level, 15 %of cross sectional area166.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
164.3DAGS
0AMH18 0670
0MWL
0MWM
166.2AMH18 0671
2DAGS
164.3CM
6.4CM

Properties (7)

additional_info
630069121620201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-16T22:25:36-08:00
documentation
PRO PIPE
is_lateral_inspection
false