Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2020, 12:27 PM
  • 01 0524_01 0523_12072020_044237.mp4

Date
12/07/2020
W/O
860479
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00206
PipeID
P01009
Time
4:27 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8267
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_860479_TV01017_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0523
Downstream MH
01 0524
Dir. of Survey
Upstream
Length Surveyed
320.1 ft.
Total Length
320.1 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
2
O&M Quick
2L00
O&M Rating
126
Overall Index
2
Overall Quick
Overall Rating
134
Pipe schematic from manhole 01 0523 to 01 0524
MH: 01 0523MH: 01 0524upstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Ends - 01 05242.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish4.4 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES26.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"29.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"77.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"226.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"228.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"274.4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"277.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"279.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"280.3 ft. HSV - Hole Soil Visible, at 01 o'clock, within 8 inches of joint: YES281.6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"318.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start320.1 ft. AMH - Downstream Manhole, Survey Begins - 01 0523320.1 ft. MWM - Water Mark, 30 %of cross sectional area320.1 ft. MWL - Water Level, 15 %of cross sectional area320.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE320.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Hole Soil Visible, at 01 o'clock, within 8 inches of joint: YES

    39.8 ft. - Hole Soil Visible, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    315.7 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
0AMH01 0523
143.7TFC
0MWM
293.5TFC
41TF
318DAGS
45.7TBA
291TFC
141.5TFC
0MWL
242.7TF
194.5TFC
2DAGS
38.5TB
320.1MGOCOCKROACHES IN MANHOLE
320.1AMH01 0524
315.7CM
191.9TFC
245.4TFC
0MGOCOCKROACHES IN MANHOLE
0MGOCONNECTION AT MH 3 O'CLOCK
39.8HSV
91.6TFC
42.8TFC
93.5TFC

Properties (7)

additional_info
630069120720003
custom_field_three
HOLE SOIL VISIBLE
custom_field_two
2
customer
1
datetime
2020-12-07T04:27:20-08:00
documentation
PRO PIPE
is_lateral_inspection
false