Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2020, 06:21 AM
  • 05 2489_05 2488_12092020_223749.mp4

Date
12/09/2020
W/O
860122
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00462
PipeID
P20884
Time
10:21 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8327
Sewer Name
05 INGLEWOOD TRUNK #1 RELIEF
City
INGLEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_860122_TV05326_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 2489
Downstream MH
05 2488
Dir. of Survey
Downstream
Length Surveyed
362.8 ft.
Total Length
362.8 ft.
Structural Index
3
Structural Quick
4121
Structural Rating
6
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 2489 to 05 2488
MH: 05 2489MH: 05 2488downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 248985.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"141.3 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Start160.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES161 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES279.8 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Finish362.8 ft. AMH - Downstream Manhole, Survey Ends - 05 2488

Observation photos (4)

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    85.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Water Level, Sag in pipe, 15 %of cross sectional area, Start

    141.3 ft. - Water Level, Sag in pipe, 15 %of cross sectional area, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    160.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES

    161 ft. - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0MWM
0MWL
279.8MWLS
85.2TB
0AMH05 2489
161RFJ
362.8AMH05 2488
141.3MWLS
160.4FM

Properties (8)

additional_info
630075120920201
custom_field_three
FRACTURE/ SAG
custom_field_two
3
customer
1
datetime
2020-12-09T22:21:50-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
35144