Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2020, 05:49 PM
  • H 1486_H 1485_12162020_095404.mp4

Date
12/16/2020
W/O
859958
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01206
PipeID
P16446
Time
9:49 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8078
Sewer Name
H JOINT OUTFALL H - UNIT 8M RELIEF
City
WEST COVINA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_859958_TV22149_NOV2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
H 1485
Downstream MH
H 1486
Dir. of Survey
Upstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole H 1485 to H 1486
MH: H 1485MH: H 1486upstream0 ft. MSA - Survey Abandoned - VIEW OF SIPHON UPLEG0.1 ft. LU - Alignment Up, 45 %0.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES0.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES0.3 ft. MGO - Reversal Inspection2.2 ft. MWM - Water Mark, 100 %of cross sectional area2.2 ft. AMH - Downstream Manhole, Survey Begins - H 14852.2 ft. MWL - Water Level, 100 %of cross sectional area

Observations (8)

DistanceCodeObservation
0MWM
0AMHH 1485
2SAP
2.2MSAVIEW OF SIPHON UPLEG
2.1LU
1.9MGO
2SSS
0MWL

Properties (7)

additional_info
630138121620062
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2020-12-16T09:49:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false