Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2020, 08:18 AM
  • 05 1773_05 1772_12182020_002425.mp4

Date
12/18/2020
W/O
0865090
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00473
PipeID
P07001
Time
12:18 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1675
Sewer Name
05 LOMITA TRUNK EXTENSION
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
20201217MDM_LOMITA_TRUNK_EXTENSION
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 1773
Downstream MH
05 1772
Dir. of Survey
Downstream
Length Surveyed
548.8 ft.
Total Length
548.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 1773 to 05 1772
MH: 05 1773MH: 05 1772downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:25AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active35 ft. MGO - General Observation - 15" VCP-CIPP107.6 ft. MGO - General Observation - POSSIBLE MINERIAL TYPE GROWTH 1%222.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Open223.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO308.1 ft. MGP - General Photograph - 15" VCP-CIPP358.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Active358.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO476.8 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Active476.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO541.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open548.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped548.8 ft. AMH - Downstream Manhole, Survey Ends - 1:05AM

Observation photos (4)

  • General Observation - 15" VCP-CIPP

    35 ft. - General Observation - 15" VCP-CIPP

  • General Observation - POSSIBLE MINERIAL TYPE GROWTH 1%

    107.6 ft. - General Observation - POSSIBLE MINERIAL TYPE GROWTH 1%

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: NO

    223.5 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO

  • General Photograph - 15" VCP-CIPP

    308.1 ft. - General Photograph - 15" VCP-CIPP

Observations (16)

DistanceCodeObservation
107.6MGOPOSSIBLE MINERIAL TYPE GROWTH 1%
358.4TBActive
0MWM
541.8TBOpen
476.8TBActive
308.1MGP15" VCP-CIPP
223.5DAGS
35MGO15" VCP-CIPP
548.8AMH1:05AM
476.8DAGS
0MWL
548.1MGOConn. @ Mh, 9 O' Clock. Capped
0AMH12:25AM
222.5TBOpen
0MGOConn. @ Mh, 9 O' Clock. Active
358.4DAGS

Properties (7)

custom_field_three
LINER GOOD COND
custom_field_two
3
customer
LACSD
datetime
2020-12-18T00:18:23-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining
CIPP