- Date
- 12/17/2020
- W/O
- 0865090
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00473
- PipeID
- P07016
- Time
- 12:06 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1674
- Sewer Name
- 05 LOMITA TRUNK EXTENSION
- City
- LOMITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- 20201217MDM_LOMITA_TRUNK_EXTENSION
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 05 1794
- Downstream MH
- 05 1793
- Dir. of Survey
- Downstream
- Length Surveyed
- 199.8 ft.
- Total Length
- 199.8 ft.
- Structural Index
- 2
- Structural Quick
- 4235
- Structural Rating
- 77
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 80
Pipe schematic from manhole 05 1794 to 05 1793 Observation photos (2)

55.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

199.1 ft. - Roots Medium Joint, from 05 to 07 o'clock, 10 %, within 8 inches of joint: YESR - INSIDE MH