- Date
- 12/03/2020
- W/O
- 855105
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00803
- PipeID
- P17240
- Time
- 11:58 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8231
- Sewer Name
- DALTON TRUNK, SECTION 3
- City
- AZUSA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_854956_TV22105_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- H 1283
- Downstream MH
- 22 0872
- Dir. of Survey
- Downstream
- Length Surveyed
- 282.1 ft.
- Total Length
- 282.1 ft.
- Structural Index
- 3
- Structural Quick
- 5J3J
- Structural Rating
- 560
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 560
Pipe schematic from manhole H 1283 to 22 0872 Observation photos (4)

2 ft. - General Observation - 80% MAG COAT

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

154.9 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES