Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2016, 11:50 AM
  • 02 0413_02 0412_8222016_050341.mp4

Date
08/22/2016
W/O
0585432
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00256
PipeID
P02735
Time
4:50 AM
Certificate
U-104-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0249
Sewer Name
02 DOWNEY-BELLFLOWER RELIEF TRUNK, SECTION 4
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
20160820MDM_DOWNEY_BELLFLOWER_RELIEF_TRUNK_SECTION_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 0413
Downstream MH
02 0412
Dir. of Survey
Downstream
Length Surveyed
293.9 ft.
Total Length
293.9 ft.
Structural Index
2
Structural Quick
352E
Structural Rating
73
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
75
Pipe schematic from manhole 02 0413 to 02 0412
MH: 02 0413MH: 02 0412downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM17.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT17.8 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE29.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped33.1 ft. MGO - General Observation - 15" VCP33.1 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H38.2 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL43.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL43.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H48.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL69 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL69 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL70.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open75.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped80.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active89.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H89.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT89.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H104.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES114.8 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H120 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H130.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H130.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL131.5 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H135.1 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL140.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL151 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL151 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H156.2 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL161 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL167.7 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open 100% ROOTS176.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL177.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped181.4 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL181.4 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL206.8 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H208.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open227.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL237.5 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H239 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open254.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open258.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL263.6 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SL274.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped283.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL288.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H293.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active293.9 ft. AMH - Downstream Manhole, Survey Ends - 5:35AM

Observation photos (1)

  • General Observation - 15" VCP

    33.1 ft. - General Observation - 15" VCP

Observations (50)

DistanceCodeObservation
227.5FCSL
33.1MGO15" VCP
237.5FCH
17.8FCSLIGHT
176.3FLSL
120FCH
181.4FCSL
48.7FLSL
130.2FCH
114.8FCH
0MWM
263.6FCSL
167.7TFDOpen 100% ROOTS
0MWL
75.8TFCapped
258.4FCSL
140.2FCSL
89.2FCH
69FCSL
131.5FCH
69FCSL
156.2FCSL
43.6FLSL
293.9AMH5:35AM
181.4FCSL
43.6FCH
0AMH4:50AM
151FCSL
135.1FCSL
151FLH
17.8FCHAIRLINE
29.2TFCCapped
33.1FLH
254.5TFOpen
38.2FCSL
89.2FCSLIGHT
89.2FCH
288.6FCH
70.2TFOpen
130.2FCSL
206.8FCH
274.8TFCCapped
104.9FC
80.9TFActive
177.7TFCCapped
283.4FCSL
293.5MGOConn. @ Mh, 3 O' Clock. Active
239TFOpen
161FCSL
208.6TFOpen

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2016-08-22T04:50:00-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false