Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2016, 11:10 AM
  • 02 0420_02 0419_8202016_044602.mp4

Date
08/20/2016
W/O
0585432
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00256
PipeID
P02742
Time
4:10 AM
Certificate
U-104-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0247
Sewer Name
02 DOWNEY-BELLFLOWER RELIEF TRUNK, SECTION 4
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
20160820MDM_DOWNEY_BELLFLOWER_RELIEF_TRUNK_SECTION_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 0420
Downstream MH
02 0419
Dir. of Survey
Downstream
Length Surveyed
253.7 ft.
Total Length
253.7 ft.
Structural Index
2
Structural Quick
322B
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
34
Pipe schematic from manhole 02 0420 to 02 0419
MH: 02 0420MH: 02 0419downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:40AM0 ft. MWM - Water Mark, 20 %of cross sectional area8.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open37.8 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE59.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped62.9 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H100.5 ft. MGO - General Observation - 15" VCP100.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open119.3 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H124.5 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL124.5 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL141.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open144.8 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H144.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H149.9 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SL155 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H165.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H170.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H171.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped185.6 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H192 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open205.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL206 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H237.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open241.9 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL241.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL253.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active253.7 ft. AMH - Downstream Manhole, Survey Ends - 5:20AM

Observation photos (1)

  • General Observation - 15" VCP

    100.5 ft. - General Observation - 15" VCP

Observations (29)

DistanceCodeObservation
253.2MGOConn. @ Mh, 3 O' Clock. Active
0MWL
0AMH4:40AM
124.5FCSL
165.3FCH
149.9FCSL
241.9FCSL
144.8FCH
100.5MGO15" VCP
185.6FLH
206FCH
171.6TFCCapped
144.8FLH
100.5TFOpen
62.9FCH
192TFOpen
170.5FCH
241.9FCSL
253.7AMH5:20AM
59.5TFCCapped
124.5FCSL
205.9FCSL
141.2TFOpen
8.4TFOpen
237.9TFOpen
119.3FCH
0MWM
155FCH
37.8FCHAIRLINE

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2016-08-20T04:10:42-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false