- Date
- 08/03/2016
- W/O
- 0580150
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00700
- PipeID
- P14781
- Time
- 2:43 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0218
- Sewer Name
- 18 SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160803MDM_SCOTT_AENUE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 18 0933
- Downstream MH
- 18 0932
- Dir. of Survey
- Downstream
- Length Surveyed
- 85.8 ft.
- Total Length
- 85.8 ft.
- Structural Index
- 2
- Structural Quick
- 5141
- Structural Rating
- 62
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 64
Pipe schematic from manhole 18 0933 to 18 0932 Observation photos (5)

8.1 ft. - Fracture Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

8.1 ft. - Hole Soil Visible, at 09 o'clock, within 8 inches of joint: YES - 1" X1" POSSIBLE SOIL VISIBLE

8.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

11.5 ft. - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SLIGHT -CHIPPED

53 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start