Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2016, 08:11 AM
  • A 0326_A 0325_6242016_014253.mp4

Date
06/24/2016
W/O
0574318
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00325
PipeID
P08236
Time
1:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0168
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20160624MDM_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
A 0326
Downstream MH
A 0325
Dir. of Survey
Downstream
Length Surveyed
5 ft.
Total Length
5 ft.
Structural Index
5
Structural Quick
5341
Structural Rating
19
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
23
Pipe schematic from manhole A 0326 to A 0325
MH: A 0326MH: A 0325downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:40AM0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 60 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM4 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM5 ft. MSA - Survey Abandoned - DOWNLEG UPSTREAM SIPHON

Observation photos (5)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM

    3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

    4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

  • Survey Abandoned - DOWNLEG UPSTREAM SIPHON

    5 ft. - Survey Abandoned - DOWNLEG UPSTREAM SIPHON

Observations (8)

DistanceCodeObservation
0AMH1:40AM
3SRVCIRCUM REBAR
3SRVCIRCUM
0MWL
0MWM
4SRVCIRCUM
2SAMSEVERE AGG
5MSADOWNLEG UPSTREAM SIPHON

Properties (7)

additional_info
DOWNLEG UPSTREAM SIPHON
custom_field_three
CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2016-06-24T01:11:45-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false