Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2016, 03:23 PM
  • 05 1265_05 1264_6222016_082438.mp4

Date
06/22/2016
W/O
0574349
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00518
PipeID
P06477
Time
8:23 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7157
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
20160616AM_SO_HAWTHORNE_WARFIELD_AV_EXT_TR_SECT_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 1265
Downstream MH
05 1264
Dir. of Survey
Downstream
Length Surveyed
266.1 ft.
Total Length
266.1 ft.
Structural Index
3
Structural Quick
4733
Structural Rating
41
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
47
Pipe schematic from manhole 05 1265 to 05 1264
MH: 05 1265MH: 05 1264downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 8:24 AM0 ft. MWL - Water Level, 10 %of cross sectional area9.2 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"17 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"19.7 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES23.7 ft. FM - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES27.7 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES31.8 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES41.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"43.8 ft. CM - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES47.8 ft. MGO - General Observation - CHIPPING47.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start60 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES68.1 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES84.3 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES85.8 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"88.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES89.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"104.4 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES116.5 ft. FM - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES138.1 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, OFFSET/MORTAR MISSING/SOIL VISIBLE142.1 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - ACTIVE, PROTRUDING IN APPROX. 2 IN, OFFSET186.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN190.6 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN221.4 ft. MGO - General Observation - CHIPPING235 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"243.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"265.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish265.7 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH265.9 ft. MGO - General Observation - ACTIVE DROP CONN. INSIDE THE MH. @ 12 O'CLOCK266.1 ft. AMH - Downstream Manhole, Survey Ends - 9:03 AM

Observation photos (15)

  • Upstream Manhole, Survey Begins - 8:24 AM

    0 ft. - Upstream Manhole, Survey Begins - 8:24 AM

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    19.7 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    23.7 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

    43.8 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

  • General Observation - CHIPPING

    47.8 ft. - General Observation - CHIPPING

  • Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    60 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    68.1 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    84.3 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    88.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES

    104.4 ft. - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    116.5 ft. - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, OFFSET/MORTAR MISSING/SOIL VISIBLE

    138.1 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, OFFSET/MORTAR MISSING/SOIL VISIBLE

  • Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - ACTIVE, PROTRUDING IN APPROX. 2 IN, OFFSET

    142.1 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - ACTIVE, PROTRUDING IN APPROX. 2 IN, OFFSET

  • Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN

    190.6 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN

  • General Observation - CHIPPING

    221.4 ft. - General Observation - CHIPPING

Observations (32)

DistanceCodeObservation
41.1TFA
138.1TFDOPEN, OFFSET/MORTAR MISSING/SOIL VISIBLE
47.8MGOCHIPPING
142.1TFDACTIVE, PROTRUDING IN APPROX. 2 IN, OFFSET
190.6TFDACTIVE, BROKEN
84.3FM
265.9MGOACTIVE DROP CONN. INSIDE THE MH. @ 12 O'CLOCK
9.2TFA
104.4FC
265.7CM
243.1TFC
27.7CL
60FM
186.7TFOPEN
47.9CM
235TFA
19.7FM
0MWM
68.1FM
43.8CM
23.7FM
88.2FM
266.1AMH9:03 AM
89.5TFA
0AMH8:24 AM
265.7MGOSLIGHT GREASE THROUGHOUT THE REACH
116.5FM
17TFA
31.8CM
0MWL
221.4MGOCHIPPING
85.8TFA

Properties (6)

custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
LACSD
datetime
2016-06-22T08:23:11-07:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false