Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2016, 03:53 PM
  • 05 2219_05 1273_6212016_085816.mp4

Date
06/21/2016
W/O
0574349
Weather
Very Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00518
PipeID
P06486
Time
8:53 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7156
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
20160616AM_SO_HAWTHORNE_WARFIELD_AV_EXT_TR_SECT_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 2219
Downstream MH
05 1273
Dir. of Survey
Downstream
Length Surveyed
272.9 ft.
Total Length
272.9 ft.
Structural Index
3
Structural Quick
5245
Structural Rating
46
O&M Index
2
O&M Quick
2311
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
53
Pipe schematic from manhole 05 2219 to 05 1273
MH: 05 2219MH: 05 1273downstream0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 8:57 AM0 ft. MWL - Water Level, 15 %of cross sectional area8.3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES9.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"16.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES20.4 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES28.3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES28.3 ft. MGO - General Observation - CHIPPING32.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start62 ft. TFI - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE62.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4" - OPEN93.1 ft. FM - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES94.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"117.2 ft. B - Broken, from 01 to 04 o'clock, within 8 inches of joint: YES118.8 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4" - OPEN121.1 ft. B - Broken, from 10 to 12 o'clock, within 8 inches of joint: YES121.1 ft. MGP - General Photograph - BROKEN145.4 ft. MGO - General Observation - CHIPPING146.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"149.4 ft. JOM - Joint Offset Medium154.7 ft. RFC - Roots Fine Connection, at 11 o'clock, within 8 inches of joint: NO154.7 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"161.5 ft. JOM - Joint Offset Medium171 ft. TFI - Tap Factory Made Intruding, at 01 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE195.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"214 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES231.7 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN234.3 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN250.6 ft. B - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES254.6 ft. MGO - General Observation - CHIPPING258.7 ft. FM - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN270.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish271.2 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK272.9 ft. AMH - Downstream Manhole, Survey Ends - 9:35 AM

Observation photos (17)

  • General Observation - CHIPPING

    28.3 ft. - General Observation - CHIPPING

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    32.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE

    62 ft. - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE

  • Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    93.1 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 01 to 04 o'clock, within 8 inches of joint: YES

    117.2 ft. - Broken, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 10 to 12 o'clock, within 8 inches of joint: YES

    121.1 ft. - Broken, from 10 to 12 o'clock, within 8 inches of joint: YES

  • General Photograph - BROKEN

    121.1 ft. - General Photograph - BROKEN

  • General Observation - CHIPPING

    145.4 ft. - General Observation - CHIPPING

  • Joint Offset Medium

    149.4 ft. - Joint Offset Medium

  • Joint Offset Medium

    161.5 ft. - Joint Offset Medium

  • Tap Factory Made Intruding, at 01 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE

    171 ft. - Tap Factory Made Intruding, at 01 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    214 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN

    231.7 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, BROKEN

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    234.3 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

    250.6 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

  • General Observation - CHIPPING

    254.6 ft. - General Observation - CHIPPING

  • Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    258.7 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

Observations (36)

DistanceCodeObservation
272.9AMH9:35 AM
20.4CL
161.5JOM
231.7TFDACTIVE, BROKEN
0MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
145.4MGOCHIPPING
118.8TBOPEN
250.6B
16.3CM
171TFIACTIVE
93.1FM
195.4TFA
32.5CM
28.3CM
271.2MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
94.1TFC
234.3FMPOSSIBLY BROKEN
121.1B
9.7TFC
149.4JOM
270.7CM
258.7FMPOSSIBLY BROKEN
146.7TFC
117.2B
28.3MGOCHIPPING
121.1MGPBROKEN
8.3CM
0MWM
62TFIACTIVE
154.7RFC
0AMH8:57 AM
0MWL
62.7TBOPEN
214FM
154.7TBA
254.6MGOCHIPPING

Properties (6)

custom_field_three
BROKEN PIPE
custom_field_two
1
customer
LACSD
datetime
2016-06-21T08:53:48-07:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false