A 0387_A 0386_6132016_010225.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SWOLLEN LAITANCE COAT
10.4 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
13.1 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
13.1 ft. - General Observation - MAG COAT 25% 8:00 TO 4:00 START
17.2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
23.4 ft. - General Observation - MAG COAT 60% START
106.2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
| Distance | Code | Observation |
|---|---|---|
| 23.4 | MGO | MAG COAT 60% START |
| 2 | SSS | SWOLLEN LAITANCE COAT |
| 10.4 | SAV | SEVERE AGG SPORATIC |
| 13.1 | SAV | SEVERE AGG |
| 0 | AMH | 12:45AM |
| 367.8 | AMH | 1:20AM |
| 8 | SSS | BLISTERING PELLING SWOLLEN CONCRETE |
| 0 | MWM | — |
| 367.4 | SSS | SWOLLEN, PEELING BLISTERING CONCRETE |
| 106.2 | SAV | SEVERE AGG SPORATIC |
| 13.1 | MGO | MAG COAT 25% 8:00 TO 4:00 START |
| 0 | MWL | — |
| 367.4 | SAV | SEVERE AGG SPORATIC |
| 17.2 | SRV | CIRCUM REBAR |
| 8 | SSS | SWOLLEN LAITANCE COAT |