A 0388_A 0387_6112016_020430.mp4
4.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SWOLLEN LAITANCE COAT
11.8 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
11.8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR POSSIBLE MISSING
18 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
24.6 ft. - General Observation - MAG COAT 30% START 10:00 TO 2:00
98.4 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
134.5 ft. - General Observation - MAG COAT 70% START
176.1 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AG
| Distance | Code | Observation |
|---|---|---|
| 410.8 | AMH | 7:35AM |
| 410.4 | SRC | CIRCUM REBAR UNDER MAG COAT |
| 134.5 | MGO | MAG COAT 70% START |
| 176.1 | SAV | SEVERE AG |
| 11.8 | SAM | SEVERE AGG |
| 410.4 | SAM | SEVERE AGG UNDER MAG COAT |
| 4.7 | SSS | SWOLLEN LAITANCE COAT |
| 18 | SRC | CIRCUM REBAR |
| 98.4 | SAV | SEVERE AGG |
| 410.4 | MGO | MAG COAT 70% FINISH |
| 0 | MWL | — |
| 24.6 | MGO | MAG COAT 30% START 10:00 TO 2:00 |
| 11.8 | SRC | CIRCUM REBAR POSSIBLE MISSING |
| 0 | AMH | 6:50AM |
| 0 | MWM | — |
| 410.4 | SSS | — |