- Date
- 06/15/2016
- W/O
- 0574349
- Weather
- Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00518
- PipeID
- P06475
- Time
- 10:11 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- 06/15/16
- Pre-Cleaning
- Jetting
- Media Label
- G7151
- Sewer Name
- 05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
- City
- REDONDO BEACH
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- 20160609AM_SO_HAWTHORNE_WARFIELD_AV_EXT_TR_SECT_4
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 05 2216
- Downstream MH
- 05 1263
- Dir. of Survey
- Downstream
- Length Surveyed
- 66.9 ft.
- Total Length
- 66.9 ft.
- Structural Index
- 2
- Structural Quick
- 3321
- Structural Rating
- 12
- O&M Index
- 3
- O&M Quick
- 3121
- O&M Rating
- 5
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 17
Pipe schematic from manhole 05 2216 to 05 1263 Observation photos (6)

0 ft. - Water Level, 5 %of cross sectional area - STAGNANT WATER

0 ft. - Upstream Manhole, Survey Begins - 10:25 AM

21.2 ft. - General Observation - CHIPPING

66.8 ft. - Roots Medium Lateral, from 12 to 05 o'clock, 45 %, within 8 inches of joint: NO - TAP ROOTS COMING OUT OF THE CONN. AS WELL

66.8 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE, 100% ROOT BLOCKAGE

66.9 ft. - Survey Abandoned - 45% ROOT MASS