Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2016, 07:46 AM
  • 18 0291_18 0290_632016_040916.mp4

Date
06/03/2016
W/O
0568850
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00702
PipeID
P14120
Time
12:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0147
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
LA MIRADA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
20160603MDM_SHOEMAKER_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
18 0291
Downstream MH
18 0290
Dir. of Survey
Downstream
Length Surveyed
165.7 ft.
Total Length
165.7 ft.
Structural Index
2
Structural Quick
3424
Structural Rating
22
O&M Index
2
O&M Quick
2500
O&M Rating
10
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 18 0291 to 18 0290
MH: 18 0291MH: 18 0290downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:10AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - GREY BUILDUP FROM MH CONN2 ft. MMC - Material Change, Vitrified clay pipe7.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE19.4 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish - SCALE20.1 ft. DAZ - Deposits Attached Other, 3 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start - SCALE24 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES28.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped30.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - HAIRLINE31.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped41.1 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H49.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H49.4 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H64.3 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - SCALE73.9 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish - SCALE78.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped81.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped86.9 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Start - SCALE100.8 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open100.8 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Finish - SCALE119.8 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H119.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H128.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped131.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped148 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES - SCALE157.2 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES157.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H165.3 ft. DAZ - Deposits Attached Other, 3 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish - SCALE165.7 ft. AMH - Downstream Manhole, Survey Ends - 4:30AM

Observation photos (5)

  • Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start - GREY BUILDUP FROM MH CONN

    2 ft. - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - GREY BUILDUP FROM MH CONN

  • Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start - SCALE

    64.3 ft. - Deposits Attached Other, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - SCALE

  • Deposits Settled Other,  5 %of cross sectional area, from 07 to 09 o'clock,  , within 8 inches of joint: YES, Start - SCALE

    86.9 ft. - Deposits Settled Other, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Start - SCALE

  • Deposits Attached Other, 5 %of cross sectional area, from 07 to 09 o'clock,  , within 8 inches of joint: YES - SCALE

    148 ft. - Deposits Attached Other, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES - SCALE

  • Deposits Attached Other, 3 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Finish - SCALE

    165.3 ft. - Deposits Attached Other, 3 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish - SCALE

Observations (32)

DistanceCodeObservation
165.3DAZSCALE
165.7AMH4:30AM
73.9DAZSCALE
119.8FCH
0MGOConn. @ Mh, 3 O' Clock. Active
81.2TFCCapped
31.5TFCCapped
86.9DSZSCALE
28.9TFCCapped
0MWM
64.3DAZSCALE
148DAZSCALE
49.4FLH
157.2CC
41.1FCH
131.5TFCCapped
100.8TBOpen
100.8DSZSCALE
119.8FLH
2DAZGREY BUILDUP FROM MH CONN
128.8TFCCapped
30.9FLHAIRLINE
24CC
7.7FLHAIRLINE
49.4FCH
0AMH4:10AM
157.2FCH
78.7TFCCapped
19.4DAZSCALE
20.1DAZSCALE
2MMC
0MWL

Properties (6)

custom_field_three
5% SCALE
custom_field_two
4
customer
LACSD
datetime
2016-06-03T00:46:39-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false