- Date
- 06/02/2016
- W/O
- 0576775
- Weather
- Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00165
- PipeID
- P10545
- Time
- 8:17 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7139
- Sewer Name
- H JOINT OUTFALL H - UNIT 1F
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Maintenance Related
- Project
- 20160602AM_JOINT_OUTFALL_H_UNIT_1F
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Upstream MH
- H 0093
- Downstream MH
- H 0092
- Dir. of Survey
- Downstream
- Length Surveyed
- 2.1 ft.
- Total Length
- 2.1 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole H 0093 to H 0092 Observation photos (6)

0 ft. - General Observation - AIRLINE

0 ft. - Water Level, 100 %of cross sectional area

0 ft. - Upstream Manhole, Survey Begins - 8:45 AM

2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

2.1 ft. - Survey Abandoned - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON