Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2016, 06:03 PM
  • 18 0278_18 0277_5242016_110534.mp4

Date
05/24/2016
W/O
0568850
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00702
PipeID
P14106
Time
11:03 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7130
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
20160523AM_SHOEMAKER_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
18 0278
Downstream MH
18 0277
Dir. of Survey
Downstream
Length Surveyed
201 ft.
Total Length
201 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole 18 0278 to 18 0277
MH: 18 0278MH: 18 0277downstream0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 11:03 AM0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - ROACHES INSIDE THE MH.0 ft. MGO - General Observation - CORRODED CHANNEL2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start2 ft. MGO - General Observation - 30% MAG COAT FROM 09 TO 03 O'CLOCK, START2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start21 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"24 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"72.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"75.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"121.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"124.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"173 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - UNKNOWN176.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"180.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES198.7 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish198.7 ft. MGO - General Observation - SLIGHT DEBRIS THROUGHOUT THE REACH198.7 ft. MGO - General Observation - 30% MAG COAT FROM 09 TO 03 O'CLOCK, FINISH198.7 ft. MGO - General Observation - SAGS THROUGHOUT THE REACH198.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish199.1 ft. MGO - General Observation - ROACHES INSIDE THE MH.199.1 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK201 ft. AMH - Downstream Manhole, Survey Ends - 11:24 AM

Observation photos (8)

  • Water Level, 35 %of cross sectional area

    0 ft. - Water Level, 35 %of cross sectional area

  • Water Mark, 50 %of cross sectional area

    0 ft. - Water Mark, 50 %of cross sectional area

  • General Observation - ROACHES INSIDE THE MH.

    0 ft. - General Observation - ROACHES INSIDE THE MH.

  • General Observation - CORRODED CHANNEL

    0 ft. - General Observation - CORRODED CHANNEL

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • General Observation - 30% MAG COAT FROM 09 TO 03 O'CLOCK, START

    2 ft. - General Observation - 30% MAG COAT FROM 09 TO 03 O'CLOCK, START

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    180.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (26)

DistanceCodeObservation
2SSS
124.4TFC
180.8FL
201AMH11:24 AM
198.7SAV
0MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
198.7MGOSLIGHT DEBRIS THROUGHOUT THE REACH
0AMH11:03 AM
121.2TFC
0MWL
2MGO30% MAG COAT FROM 09 TO 03 O'CLOCK, START
72.8TFC
0MWM
75.7TFC
199.1MGOROACHES INSIDE THE MH.
198.7MGO30% MAG COAT FROM 09 TO 03 O'CLOCK, FINISH
24TFC
198.7MGOSAGS THROUGHOUT THE REACH
176.2TFC
0MGOROACHES INSIDE THE MH.
0MGOCORRODED CHANNEL
198.7SSS
199.1MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
2SAV
173TFUNKNOWN
21TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-05-24T11:03:14-07:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false