Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 25, 2016, 03:57 PM
  • 18 0274_18 0273_5252016_092339.mp4

Date
05/25/2016
W/O
0568850
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00702
PipeID
P14102
Time
8:57 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7131
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
20160523AM_SHOEMAKER_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
18 0274
Downstream MH
18 0273
Dir. of Survey
Downstream
Length Surveyed
367.3 ft.
Total Length
367.3 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 0274 to 18 0273
MH: 18 0274MH: 18 0273downstream0 ft. AMH - Upstream Manhole, Survey Begins - 9:22 AM0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - ROACHES INSIDE THE MH.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start16.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"20.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"65.6 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"68.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"117.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"119.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"168.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"171.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"214 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"217.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"265.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"269.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"317.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"320.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"365 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish365 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish366 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK366 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK366 ft. MGO - General Observation - ROACHES INSIDE THE MH.367.3 ft. AMH - Downstream Manhole, Survey Ends - 9:54 AM

Observation photos (7)

  • Upstream Manhole, Survey Begins - 9:22 AM

    0 ft. - Upstream Manhole, Survey Begins - 9:22 AM

  • Water Level, 35 %of cross sectional area

    0 ft. - Water Level, 35 %of cross sectional area

  • Water Mark, 50 %of cross sectional area

    0 ft. - Water Mark, 50 %of cross sectional area

  • General Observation - ROACHES INSIDE THE MH.

    0 ft. - General Observation - ROACHES INSIDE THE MH.

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    16.9 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"

Observations (26)

DistanceCodeObservation
366MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
16.9TFC
214TFC
2SAV
117.1TFC
317.6TFC
365SSS
2SSS
0AMH9:22 AM
0MWL
171.8TFC
269.1TFA
168.4TFC
365SAV
65.6TFA
265.9TFC
0MWM
367.3AMH9:54 AM
366MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
20.3TFC
217.4TFC
68.7TFC
119.9TFA
0MGOROACHES INSIDE THE MH.
366MGOROACHES INSIDE THE MH.
320.8TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-05-25T08:57:29-07:00
documentation
MIRANDA & FRANKLIN
is_lateral_inspection
false