Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2016, 04:17 PM
  • 15 0373_15 0372_5212016_092042.mp4

Date
05/21/2016
W/O
0563341
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00598
PipeID
P12299
Time
9:17 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7127
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
18
Purpose
Routine Assessment
Project
20160521AM_BALDWIN_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
15 0373
Downstream MH
15 0372
Dir. of Survey
Downstream
Length Surveyed
361.1 ft.
Total Length
361.1 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 15 0373 to 15 0372
MH: 15 0373MH: 15 0372downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MGO - General Observation - ROACHES INSIDE THE MH.0 ft. AMH - Upstream Manhole, Survey Begins - 9:19 AM0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. MMC - Material Change, Other (state in comments) - CONCRETE PIPE15.4 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"34.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES68.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"101.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN150.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"190.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"275.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6", 6"339 ft. MMC - Material Change, Vitrified clay pipe343 ft. MWL - Water Level, 70 %of cross sectional area344.9 ft. MMC - Material Change, Other (state in comments) - CONCRETE PIPE344.9 ft. JSL - Joint Separated Large344.9 ft. MGO - General Observation - CHIPPING ALL AROUND THE JOINT358.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish358.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish359.4 ft. MGO - General Observation - ROACHES INSIDE THE MH.359.4 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK361.1 ft. AMH - Downstream Manhole, Survey Ends - 9:47 AM

Observation photos (1)

  • Material Change, Vitrified clay pipe

    339 ft. - Material Change, Vitrified clay pipe

Observations (24)

DistanceCodeObservation
0MWL
0MGOROACHES INSIDE THE MH.
150.3TFC
359.4MGOROACHES INSIDE THE MH.
0AMH9:19 AM
0MWM
344.9MMCCONCRETE PIPE
190.7TFA
358.7SSS
358.7SAV
343MWL
361.1AMH9:47 AM
34.6CM
344.9JSL
339MMC
2SAV
2SSS
2MMCCONCRETE PIPE
15.4TFA
68.9TFA
344.9MGOCHIPPING ALL AROUND THE JOINT
359.4MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
275.9TFA
101.1TFOPEN

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-05-21T09:17:34-07:00
documentation
MIRANDA & FRANKLIN
is_lateral_inspection
false