Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 17, 2016, 07:56 PM
  • C 0171_C 0170_5172016_125813.mp4

Date
05/17/2016
W/O
0568717
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00130
PipeID
P09695
Time
12:56 PM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7122
Sewer Name
C JOINT OUTFALL C - UNIT 5C
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
10
Purpose
Routine Assessment
Project
20160517AM_JOINT_OUTFALL_C_UNIT_5C
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
C 0171
Downstream MH
C 0170
Dir. of Survey
Downstream
Length Surveyed
333.5 ft.
Total Length
333.5 ft.
Structural Index
4
Structural Quick
5532
Structural Rating
35
O&M Index
2
O&M Quick
2500
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
45
Pipe schematic from manhole C 0171 to C 0170
MH: C 0171MH: C 0170downstream0 ft. AMH - Upstream Manhole, Survey Begins - ABANDONED MH.0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area1.6 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 01 to 04 o'clock, , within 8 inches of joint: NO2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start6.6 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO108.6 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO130.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish130.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish133.3 ft. MGO - General Observation - ACTIVE DROP CONN. INSIDE THE MH. @ 09 O'CLOCK133.3 ft. MGO - General Observation - ROACHES INSIDE THE MH.133.4 ft. MGO - General Observation - UNMAPPED MH.136.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start136.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start187.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES218.2 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Start221.7 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Finish236.9 ft. SRV - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO250.2 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO275.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 04 o'clock, , within 8 inches of joint: YES284.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES308 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES331.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish331.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish331.8 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 02 O'CLOCK331.8 ft. MGO - General Observation - ROACHES INSIDE THE MH.331.8 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 12 O'CLOCK333.5 ft. AMH - Downstream Manhole, Survey Ends - 1:29 PM

Observation photos (17)

  • Upstream Manhole, Survey Begins - ABANDONED MH.

    0 ft. - Upstream Manhole, Survey Begins - ABANDONED MH.

  • Water Level, 30 %of cross sectional area

    0 ft. - Water Level, 30 %of cross sectional area

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 01 to 04 o'clock,  , within 8 inches of joint: NO

    1.6 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 01 to 04 o'clock, , within 8 inches of joint: NO

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

    6.6 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

    108.6 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

  • General Observation - ACTIVE DROP CONN. INSIDE THE MH. @ 09 O'CLOCK

    133.3 ft. - General Observation - ACTIVE DROP CONN. INSIDE THE MH. @ 09 O'CLOCK

  • General Observation - ROACHES INSIDE THE MH.

    133.3 ft. - General Observation - ROACHES INSIDE THE MH.

  • General Observation - UNMAPPED MH.

    133.4 ft. - General Observation - UNMAPPED MH.

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    136.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    136.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock,  , within 8 inches of joint: YES

    187.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Start

    218.2 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Finish

    221.7 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Finish

  • Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO

    236.9 ft. - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

    250.2 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

Observations (29)

DistanceCodeObservation
331.5SSS
331.8MGOACTIVE CONN. INSIDE THE MH. @ 02 O'CLOCK
6.6SRV
250.2SRV
0AMHABANDONED MH.
0MWM
130.9SAV
308DAE
133.3MGOACTIVE DROP CONN. INSIDE THE MH. @ 09 O'CLOCK
133.3MGOROACHES INSIDE THE MH.
0MWL
136.4SAV
284.3DAE
333.5AMH1:29 PM
2SSS
133.4MGOUNMAPPED MH.
331.5SAV
331.8MGOROACHES INSIDE THE MH.
130.9SSS
275.6DAE
236.9SRV
187.1DAE
331.8MGOACTIVE CONN. INSIDE THE MH. @ 12 O'CLOCK
108.6SRV
221.7SRV
218.2SRV
2SAV
1.6DAE
136.4SSS

Properties (6)

custom_field_three
REBAR
custom_field_two
2
customer
LACSD
datetime
2016-05-17T12:56:45-07:00
documentation
MIRANDA, SHADLER, FRANKLIN
is_lateral_inspection
false