Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 13, 2016, 06:54 PM
  • 18 0579_18 0284_5132016_122806.mp4

Date
05/13/2016
W/O
0568850
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z00702
PipeID
P14113
Time
11:54 AM
Certificate
U-115-06022628
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7118
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
20160513MI_SHOEMAKER_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
18 0579
Downstream MH
18 0284
Dir. of Survey
Downstream
Length Surveyed
366.9 ft.
Total Length
366.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0579 to 18 0284
MH: 18 0579MH: 18 0284downstream0 ft. MGO - General Observation - CONNECTION AT MH, 3 OCLOCK, ACTIVE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:30PM2.4 ft. MGO - General Observation - MAGNESIUM HYDROXIDE COATING, FROM 7 TO 5 OCLOCK , 80%25 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"31.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"81.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"126.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"178 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"278.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"281.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"329.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"366.9 ft. MGO - General Observation - ROACHES AT MH366.9 ft. MGO - General Observation - CONNECTION AT MH, 9 OCLOCK, UNKNOWN366.9 ft. AMH - Downstream Manhole, Survey Ends - 12:50PM

Observation photos (2)

  • General Observation - MAGNESIUM HYDROXIDE COATING, FROM 7 TO 5 OCLOCK , 80%

    2.4 ft. - General Observation - MAGNESIUM HYDROXIDE COATING, FROM 7 TO 5 OCLOCK , 80%

  • Downstream Manhole, Survey Ends - 12:50PM

    366.9 ft. - Downstream Manhole, Survey Ends - 12:50PM

Observations (18)

DistanceCodeObservation
329.8TFC
366.9MGOROACHES AT MH
0MGOCONNECTION AT MH, 3 OCLOCK, ACTIVE
178TFC
0MWM
366.9MGOCONNECTION AT MH, 9 OCLOCK, UNKNOWN
126.4TFC
2.4MGOMAGNESIUM HYDROXIDE COATING, FROM 7 TO 5 OCLOCK , 80%
128.9TFC
81.1TFC
366.9AMH12:50PM
31.1TFC
0MWL
0AMH12:30PM
281.1TFC
25TFC
278.2TFC
332.8TFC

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2016-05-13T11:54:00-07:00
documentation
IGNACIO, SHADLER
is_lateral_inspection
false