C 0311_C 0310_562016_085642.mp4
0 ft. - Water Mark, 35 %of cross sectional area
0 ft. - Water Level, 25 %of cross sectional area
0 ft. - General Observation - CAPPED CONN. INSIDE THE MH. @ 06 O'CLOCK
0 ft. - Upstream Manhole, Survey Begins - 8:56 AM
2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: NO
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start
301.9 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, 40% BLOCKED, POSSIBLE BREAK-IN CONN.
411.6 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES
411.6 ft. - General Photograph - REBAR
892.1 ft. - General Observation - MAG COAT SPORADICALLY THROUGHOUT THE REACH FROM 09 TO 03 O'CLOCK
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 0 | MWL | — |
| 2 | DAGS | — |
| 0 | MGO | CAPPED CONN. INSIDE THE MH. @ 06 O'CLOCK |
| 892.1 | MGO | MAG COAT SPORADICALLY THROUGHOUT THE REACH FROM 09 TO 03 O'CLOCK |
| 763.3 | TF | OPEN, POSSIBLE BREAK-IN |
| 151.2 | TB | OPEN |
| 892.1 | MGO | SLIGHT SAGS THROUGHOUT THE REACH |
| 10.5 | SRV | — |
| 411.6 | SRV | — |
| 892.1 | SAV | — |
| 2 | SAV | — |
| 301.9 | TFD | OPEN, 40% BLOCKED, POSSIBLE BREAK-IN CONN. |
| 2 | SRV | — |
| 2 | SSS | — |
| 893.8 | AMH | 9:49 AM |
| 568.3 | TF | OPEN |
| 411.6 | MGP | REBAR |
| 0 | AMH | 8:56 AM |
| 892.1 | SSS | — |