Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2016, 07:40 AM
  • 08 0036_08 0035_532016_025436.mp4

Date
05/03/2016
W/O
0563840
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00038
Time
12:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0119
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20160503MDM_MAIN_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
08 0036
Downstream MH
08 0035
Dir. of Survey
Downstream
Length Surveyed
323.8 ft.
Total Length
323.8 ft.
Structural Index
3
Structural Quick
433A
Structural Rating
60
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
60
Pipe schematic from manhole 08 0036 to 08 0035
MH: 08 0036MH: 08 0035downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:45AM19.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE32.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped34.2 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE34.5 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H54.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE55.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - HAIRLINE58.6 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT58.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE62.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - SLIGHT64.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Finish - H64.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - H83.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped97.6 ft. MGO - General Observation - 21" VCP124.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES132 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped185 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT185.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped190.4 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H191.1 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT & CHIPPED PIPE193.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT195.2 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES - SLIGHT195.2 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT203.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT205.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SLIGHT233.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped266.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H268.8 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H271.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H275 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H276.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped278.1 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H289.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H292.6 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SLIGHT323.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H323.8 ft. AMH - Downstream Manhole, Survey Ends - 3:25AM

Observation photos (7)

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    55.8 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

  • Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    58.6 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    58.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    185 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H

    190.4 ft. - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    193.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES - SLIGHT

    195.2 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (39)

DistanceCodeObservation
0MGOConn. @ Mh, 9 O' Clock. Active
132TFCCapped
203.4FMSLIGHT
0MWL
97.6MGO21" VCP
58.6FLSLIGHT
64.9FLH
34.2FLHAIRLINE
54.8FLHAIRLINE
278.1FLH
292.6FCSLIGHT
190.4FCH
195.2FMSLIGHT
271.8FCH
185FLSLIGHT
64.9FMH
268.8FCH
191.1FLSLIGHT & CHIPPED PIPE
276.5TFCCapped
34.5FCH
32.3TFCCapped
275FLH
205.6FLSLIGHT
124.6CL
55.8FLHAIRLINE
62.3FLSLIGHT
58.6FMHAIRLINE
83.7TFCCapped
0MWM
193.7FMSLIGHT
323.8AMH3:25AM
323.3FLH
266.3FLH
195.2FLSLIGHT
0AMH2:45AM
19.8FLHAIRLINE
185.6TFCCapped
289.8FLH
233.6TFCCapped

Properties (6)

custom_field_three
MULTIPLE SLIGHT FRACTURES JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2016-05-03T00:40:12-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false