Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2020, 08:41 AM
  • 22 0705_22 0704_12082020_011848.mp4

Date
12/08/2020
W/O
860127
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00826
PipeID
P17058
Time
12:41 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8071
Sewer Name
22 SAN DIMAS CONNECTION EXTENSION TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_860127_TV22167_NOV2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0705
Downstream MH
22 0704
Dir. of Survey
Downstream
Length Surveyed
411.8 ft.
Total Length
411.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 22 0705 to 22 0704
MH: 22 0705MH: 22 0704downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 07050 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start33.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"61.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"179.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"183.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"235.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"282.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"289.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"329.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"405.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish408.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish411.8 ft. AMH - Downstream Manhole, Survey Ends - 22 0704

Observation photos (1)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    282.3 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

Observations (16)

DistanceCodeObservation
33.6TFC
0MWM
289.9TFC
61.9TFC
408.5SAV
2SAV
405.8DAGS
183.5TB
0AMH22 0705
329.5TFC
179.8TFC
0MWL
282.3TF
235.1TF
2DAGS
411.8AMH22 0704

Properties (7)

additional_info
630075120720202
custom_field_three
GREASE
custom_field_two
3
customer
1
datetime
2020-12-08T00:41:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false