Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 6, 2017, 11:04 AM
Date
06/06/2017
W/O
641198
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01131
PipeID
P25269
Time
4:04 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3962
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_641198_TV05127_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2567
Downstream MH
05 2568
Dir. of Survey
Upstream
Length Surveyed
282.8 ft.
Total Length
282.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 2567 to 05 2568
MH: 05 2567MH: 05 2568upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 25681.8 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish276.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start282.7 ft. MWM - Water Mark, 65 %of cross sectional area282.8 ft. AMH - Downstream Manhole, Survey Begins - 05 2567282.8 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    6.5 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
282.8AMH05 2568
6.5DAGS
0.1MWM
0AMH05 2567
281DAGS
0MWL

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2017-06-06T04:04:14-07:00
is_lateral_inspection
false
year_laid
38590