Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2016, 10:46 AM
  • A 0512_A 0511_3232016_040808.mp4

Date
03/23/2016
W/O
0552352
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00315
PipeID
P07748
Time
3:46 AM
Certificate
U-1014-0602253
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0098
Sewer Name
A JOA-1A DISTRICT 5 INTERCEPTOR
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
20
Purpose
Capital Improvement Program Assesment
Project
20160321MDM_JOA_1A_DISTRICT_5_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Upstream MH
A 0512
Downstream MH
A 0511
Dir. of Survey
Downstream
Length Surveyed
657.8 ft.
Total Length
657.8 ft.
Structural Index
5
Structural Quick
5842
Structural Rating
48
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
48
Pipe schematic from manhole A 0512 to A 0511
MH: A 0512MH: A 0511downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG13.7 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - CIRCUM25.5 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR31.9 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM43.9 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - COIRCUM69.5 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM87.6 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM98.2 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM112.9 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC195.3 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR195.3 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR SPORATIC386 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG463.3 ft. MGP - General Photograph - 54" RCP657.1 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM657.1 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG657.8 ft. AMH - Downstream Manhole, Survey Ends - 4:40AM

Observation photos (10)

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM

    2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    25.5 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - COIRCUM

    43.9 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - COIRCUM

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM

    87.6 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

    98.2 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

    112.9 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    195.3 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    386 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Photograph - 54" RCP

    463.3 ft. - General Photograph - 54" RCP

Observations (20)

DistanceCodeObservation
657.8AMH4:40AM
98.2SRVCIRCUM
2SRVCIRCUM
195.3SRVCIRCUM REBAR
13.7SRVCIRCUM
195.3SRVCIRCUM REBAR SPORATIC
386SAMSEVERE AGG
657.1SRVCIRCUM
0MWM
2SAMSEVERE AGG
463.3MGP54" RCP
87.6SRVCIRCUM
0AMH3:50AM
112.9SRVCIRCUM REBAR SPORATIC
25.5SRVCIRCUM REBAR
43.9SRVCOIRCUM
0MWL
31.9SRVCIRCUM
69.5SRVCIRCUM
657.1SAMSEVERE AGG

Properties (6)

custom_field_three
VISIBLE CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2016-03-23T03:46:50-07:00
documentation
MARTIM,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false