Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2016, 07:27 AM
Date
03/15/2016
W/O
0557681
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11482
Time
12:27 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6672
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Capital Improvement Program Assesment
Project
20160315MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0235A
Downstream MH
J 0235
Dir. of Survey
Downstream
Length Surveyed
82.6 ft.
Total Length
82.6 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
34
Pipe schematic from manhole J 0235A to J 0235
MH: J 0235AMH: J 0235downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN ACTIVE 3:000 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT2 ft. MGO - General Observation - MAG COAT 98% START26.2 ft. SSS - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO82.2 ft. MGO - General Observation - MH CONN STUB 9:0082.2 ft. MGO - General Observation - MH CONN STUB 3:0082.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING LAITANCE COAT UNDER MAG COAT82.2 ft. MGO - General Observation - MAG COAT 98% FINISH82.6 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT

  • General Observation - MAG COAT 98% START

    2 ft. - General Observation - MAG COAT 98% START

  • Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO

    26.2 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO

Observations (12)

DistanceCodeObservation
82.2MGOMH CONN STUB 9:00
0MWM
82.2MGOMH CONN STUB 3:00
82.2SSSBLISTERING LAITANCE COAT UNDER MAG COAT
82.2MGOMAG COAT 98% FINISH
0MWL
0MGOMH CONN ACTIVE 3:00
82.6AMH1:30AM
0AMH1:20AM
26.2SSS
2SSSBLISTERING PEELING LAITANCE COAT
2MGOMAG COAT 98% START

Properties (6)

custom_field_three
SPALLING
custom_field_two
3
customer
LACSD
datetime
2016-03-15T00:27:31-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false