Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2016, 10:08 AM
  • 02 1351_02 1350_372016_023339.mp4

Date
03/07/2016
W/O
0541751
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00277
PipeID
P03874
Time
2:08 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0082
Sewer Name
02 JANE STREET BRANCH TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Routine Assessment
Project
20160302MDM_JANE_STREET_BRANCH_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 1351
Downstream MH
02 1350
Dir. of Survey
Downstream
Length Surveyed
378.1 ft.
Total Length
378.1 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1351 to 02 1350
MH: 02 1351MH: 02 1350downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:25AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. MWL - Water Level, 10 %of cross sectional area34.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE37.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE151.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open302.7 ft. MGP - General Photograph - 21" VCP378.1 ft. AMH - Downstream Manhole, Survey Ends - 2:50AM=ABANDONED MH=CAPPED

Observation photos (2)

  • General Photograph - 21" VCP

    302.7 ft. - General Photograph - 21" VCP

  • Downstream Manhole, Survey Ends - 2:50AM=ABANDONED MH=CAPPED

    378.1 ft. - Downstream Manhole, Survey Ends - 2:50AM=ABANDONED MH=CAPPED

Observations (9)

DistanceCodeObservation
0MWM
302.7MGP21" VCP
0AMH2:25AM
151.3TFOpen
37.7FLHAIRLINE
378.1AMH2:50AM=ABANDONED MH=CAPPED
0MGOConn. @ Mh, 9 O' Clock. OPEN
0MWL
34.6FLHAIRLINE

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2016-03-07T02:08:21-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false