Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2015, 07:18 PM
  • 29 0315_29 0312_1272015_114840.mp4

Date
12/07/2015
W/O
0545386
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z01015
PipeID
P24330
Time
11:18 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7008
Sewer Name
29 EASTSIDE INTERCEPTOR SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Maintenance Related
Project
20151207AM_EASTSIDE_INTERCEPTOR_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0315
Downstream MH
29 0312
Dir. of Survey
Downstream
Length Surveyed
92.6 ft.
Total Length
92.6 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 29 0315 to 29 0312
MH: 29 0315MH: 29 0312downstream0 ft. AMH - Upstream Manhole, Survey Begins - 11:35 AM, EMERGENCY INSPECTION, MH. HAS A DRAIN COVER0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - OPEN CONN. INSIDE THE MH. @ 03 O'CLOCK, 50% BLOCKED2.1 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, BROKEN89.3 ft. BSV - Broken Soil Visible, from 07 to 12 o'clock, within 8 inches of joint: NO92 ft. OBM - Obstacles Pipe Material, 10 %of cross sectional area, from 05 to 07 o'clock92.6 ft. MSA - Survey Abandoned - INSPECTION COMPLETED ON A REVERSE PULL

Observation photos (4)

  • Upstream Manhole, Survey Begins - 11:35 AM, EMERGENCY INSPECTION, MH. HAS A DRAIN COVER

    0 ft. - Upstream Manhole, Survey Begins - 11:35 AM, EMERGENCY INSPECTION, MH. HAS A DRAIN COVER

  • General Observation - OPEN CONN. INSIDE THE MH. @ 03 O'CLOCK, 50% BLOCKED

    0 ft. - General Observation - OPEN CONN. INSIDE THE MH. @ 03 O'CLOCK, 50% BLOCKED

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, BROKEN

    2.1 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, BROKEN

  • Broken Soil Visible, from 07 to 12 o'clock, within 8 inches of joint: NO

    89.3 ft. - Broken Soil Visible, from 07 to 12 o'clock, within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
0AMH11:35 AM, EMERGENCY INSPECTION, MH. HAS A DRAIN COVER
0MWL
89.3BSV
92OBM
0MGOOPEN CONN. INSIDE THE MH. @ 03 O'CLOCK, 50% BLOCKED
2.1TFDACTIVE, BROKEN
92.6MSAINSPECTION COMPLETED ON A REVERSE PULL

Properties (7)

additional_info
EMERGENCY INSPECTION, LOOKING FOR MISSING PIPE
custom_field_three
EMERGENCY INSPECTION
custom_field_two
5
customer
LACSD
datetime
2015-12-07T11:18:27-08:00
documentation
MIRANDA, SHADLER, IGNACIO, MIRABAL
is_lateral_inspection
false