Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2015, 06:22 PM
  • 29 0315_29 0312_1272015_104054.mp4

Date
12/07/2015
W/O
0545386
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z01015
PipeID
P24330
Time
10:22 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7008
Sewer Name
29 EASTSIDE INTERCEPTOR SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Maintenance Related
Project
20151207AM_EASTSIDE_INTERCEPTOR_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0312
Downstream MH
29 0315
Dir. of Survey
Upstream
Length Surveyed
122 ft.
Total Length
122 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 29 0312 to 29 0315
MH: 29 0312MH: 29 0315upstream0 ft. MSA - Survey Abandoned - CAN'T TRACTOR OVER BROKEN PIPE0.1 ft. BSV - Broken Soil Visible, from 12 to 05 o'clock, within 8 inches of joint: YES0.9 ft. OBM - Obstacles Pipe Material, 10 %of cross sectional area, from 05 to 07 o'clock122 ft. MWL - Water Level, 5 %of cross sectional area122 ft. AMH - Downstream Manhole, Survey Begins - 10:40 AM, EMERGENCY INSPECTION

Observation photos (4)

  • Water Level, 5 %of cross sectional area

    0 ft. - Water Level, 5 %of cross sectional area

  • Downstream Manhole, Survey Begins - 10:40 AM, EMERGENCY INSPECTION

    0 ft. - Downstream Manhole, Survey Begins - 10:40 AM, EMERGENCY INSPECTION

  • Obstacles Pipe Material, 10 %of cross sectional area, from 05 to 07 o'clock

    121.1 ft. - Obstacles Pipe Material, 10 %of cross sectional area, from 05 to 07 o'clock

  • Broken Soil Visible, from 12 to 05 o'clock, within 8 inches of joint: YES

    121.9 ft. - Broken Soil Visible, from 12 to 05 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
122MSACAN'T TRACTOR OVER BROKEN PIPE
121.9BSV
0MWL
121.1OBM
0AMH10:40 AM, EMERGENCY INSPECTION

Properties (7)

additional_info
EMERGENCY INSPECTION, LOOKING FOR MISSING PIPE
custom_field_three
EMERGENCY
custom_field_two
5
customer
LACSD
datetime
2015-12-07T10:22:08-08:00
documentation
MIRANDA, SHADLER, IGNACIO, MIRABAL
is_lateral_inspection
false