Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2020, 10:09 AM
  • H 1411_H 1410_12042020_021118.mp4

Date
12/04/2020
W/O
860085
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01204
PipeID
P16282
Time
2:09 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8261
Sewer Name
H JOINT OUTFALL H - UNIT 8M
City
WEST COVINA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
30
Purpose
Routine Assessment
Project
RFIR_WO_860085_TV22122_NOV2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 1410
Downstream MH
H 1411
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole H 1410 to H 1411
MH: H 1410MH: H 1411upstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SE SIPHON.2 ft. MWL - Water Level, 50 %of cross sectional area2 ft. MWM - Water Mark, 70 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - H 1410, SE SIPHON

Observation photos (1)

  • Survey Abandoned - VIEW OF UPLEG OF D/S SE SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SE SIPHON.

Observations (4)

DistanceCodeObservation
0MWL
2MSAVIEW OF UPLEG OF D/S SE SIPHON.
0MWM
0AMHH 1410, SE SIPHON

Properties (7)

additional_info
630069120320202
custom_field_three
NO VISIBLE DEFECTS
custom_field_two
4
customer
1
datetime
2020-12-04T02:09:54-08:00
documentation
PRO PIPE
is_lateral_inspection
false