Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2015, 04:37 PM
  • 02 0162_02 0161_1292015_094415.mp4

Date
12/09/2015
W/O
0536410
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00251
PipeID
P02465
Time
8:37 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7011
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
20151204AM_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
02 0162
Downstream MH
02 0161
Dir. of Survey
Downstream
Length Surveyed
333.8 ft.
Total Length
333.8 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
10
Pipe schematic from manhole 02 0162 to 02 0161
MH: 02 0162MH: 02 0161downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 9:42 AM0 ft. MGO - General Observation - ROACHES INSIDE THE MH.0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK0 ft. MGO - General Observation - CAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area14.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start34.2 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Start35.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"39.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES39.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Finish80.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"86.2 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 4" - OPEN92.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"116.3 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 4" - OPEN135 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"153 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"223.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"226.5 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE, 20% ROOTS241.6 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, 10% BLOCKED253.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"332.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish332.5 ft. MGO - General Observation - ROACHES INSIDE THE MH.332.5 ft. MGO - General Observation - CAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK332.5 ft. MGO - General Observation - CAPPED CONN. INSIDE THE MH. @ 03 O'CLOCK333.8 ft. AMH - Downstream Manhole, Survey Ends - 10:08 AM

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    14.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE, 20% ROOTS

    226.5 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE, 20% ROOTS

Observations (26)

DistanceCodeObservation
39.6CL
0MWL
226.5TFDACTIVE, 20% ROOTS
86.2TBOPEN
14.2DAGS
34.2CL
253.9TFA
332.5MGOROACHES INSIDE THE MH.
0AMH9:42 AM
332.5MGOCAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK
80.6TFC
223.5TFC
0MGOROACHES INSIDE THE MH.
0MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
39.6CL
116.3TBOPEN
153TFC
0MGOCAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK
333.8AMH10:08 AM
135TFC
92.8TFC
332.1DAGS
35.2TFC
332.5MGOCAPPED CONN. INSIDE THE MH. @ 03 O'CLOCK
241.6TFDOPEN, 10% BLOCKED
0MWM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-12-09T08:37:45-08:00
documentation
MIRANDA, FRANKLIN, SHADLER, MIRABAL
is_lateral_inspection
false