- Date
- 12/09/2015
- W/O
- 0536410
- Weather
- Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00251
- PipeID
- P02467
- Time
- 8:36 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7011
- Sewer Name
- 02 DOWNEY-BELLFLOWER TRUNK
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- 20151204AM_DOWNEY_BELLFLOWER_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 02 0164
- Downstream MH
- 02 0163
- Dir. of Survey
- Downstream
- Length Surveyed
- 336.2 ft.
- Total Length
- 336.2 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 02 0164 to 02 0163 Observation photos (1)

23 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT