Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 11, 2020, 08:02 AM
  • 02 1754_02 1753_12112020_002624.mp4

Date
12/11/2020
W/O
0865140
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00254
PipeID
P04097
Time
12:02 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1666
Sewer Name
02 DOWNEY-BELLFLOWER EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
15
Purpose
Routine Assessment
Project
20201210MDM_DOWNEY_BELLFLOWER_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
02 1754
Downstream MH
02 1753
Dir. of Survey
Downstream
Length Surveyed
372.5 ft.
Total Length
372.5 ft.
Structural Index
2
Structural Quick
332G
Structural Rating
93
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
97
Pipe schematic from manhole 02 1754 to 02 1753
MH: 02 1754MH: 02 1753downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:25AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: NO - SLIGHT9.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT9.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT10.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start17.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL25.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL37.8 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL54.1 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - HAIRLINE66.8 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H74.5 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL78.7 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL87.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open93.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL97.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL122.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H122.1 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL126.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H150.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL158.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES, - SL166.6 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - SL170.7 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL186.8 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL191.1 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL195.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL199.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL203.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SWL211.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES211.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open218.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL222.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL234.6 ft. FC - Fracture Circumferential, from 09 to 04 o'clock, within 8 inches of joint: YES - SL235.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish242.8 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES271.1 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL275.1 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL279.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL287.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL291.7 ft. FC - Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES - H295.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL295.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H307.5 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL314.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL324.1 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL336.4 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H352.2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL352.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open354.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H357.7 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H363.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H366.7 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL369.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - H372 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active372 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped372.5 ft. AMH - Downstream Manhole, Survey Ends - 1:15AM

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    10.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (58)

DistanceCodeObservation
279.7FCSL
78.7FCSL
150.5FCSL
307.5FCSL
271.1FCSL
235.2DAGS
122.1FLH
352.2FCSL
122.1FCSL
211.8DAGS
166.6FCSL
74.5FCSL
372MGOConn. @ Mh, 3 O' Clock. Active
54.1FCHAIRLINE
66.8FCH
363.6FCH
25.9FCSL
10.1DAGS
17.7FCSL
9.6FCSLIGHT
170.7FCSL
234.6FCSL
126.2FLH
97.9FCSL
352.2TFOpen
275.1FCSL
295.4FCSL
369.9FCH
222.6FCSL
186.8FCSL
372.5AMH1:15AM
195.2FCSL
2FCSLIGHT
158.5FCSL
357.7FCH
37.8FCSL
354.4FCH
372MGOConn. @ Mh, 9 O' Clock. Capped
9.6FCSLIGHT
314.8FCSL
366.7FCSL
0MWM
336.4FLH
87.2TFOpen
199.2FCSL
93.8FCSL
203.2FCSWL
218.4FCSL
295.4FCH
191.1FCSL
242.8FC
0AMH12:25AM
211.8TFOpen
0MWL
0MGOConn. @ Mh, 9 O' Clock. Capped
287.3FCSL
324.1FCSL
291.7FCH

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2020-12-11T00:02:07-08:00
documentation
MARTIN,OLIVER 111,RUVALCABA
is_lateral_inspection
false