Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 25, 2019, 10:10 AM
  • 08-0365-08-0364.mpg

Date
06/25/2019
W/O
200347
Weather
Dry
Operator/Surveyor
Oscar Villarreal
Sewer ID
Z00003
PipeID
P00417
Time
3:10 AM
Certificate
U-1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
03
Sewer Name
08 Davidson City Trunk
City
City of Carson, CA
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Post-Rehabilitation Survey
Project
Davidson_City_TS_Rehab
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
18 in.
Upstream MH
08 0365
Downstream MH
08 0364
Dir. of Survey
Downstream
Length Surveyed
141 ft.
Total Length
141 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 08 0365 to 08 0364
MH: 08 0365MH: 08 0364downstream0 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - retert0 ft. AMH - Upstream Manhole, Survey Begins - MH 3650 ft. MWL - Water Level, 5 % of cross sectional area0 ft.28.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES32.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES64 ft. TFC - Tap Factory Made Capped, at 12 o'clock, 6", within 8 inches of joint: YES94 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES96.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES118 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES122 ft. LFW - Lining Failure Wrinkled, at 03 o'clock, within 8 inches of joint: YES, Start122.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, 8", within 8 inches of joint: YES133 ft. LFW - Lining Failure Wrinkled, at 03 o'clock, within 8 inches of joint: YES, Finish140.4 ft. AMH - Downstream Manhole, Survey Ends - MH 364141 ft. AMH - Downstream Manhole, Survey Ends - MH 364

Observations (16)

DistanceCodeObservation
122.2TFA
0MWL
96.7TFA
133LFW
32.9TFA
122LFW
0AMHretert
141AMHMH 364
94TFA
118TFA
28.8TFA
140.4AMHMH 364
0AMHMH 365
0MWL
64TFC
0

Properties (3)

customer
LACSD
datetime
2019-06-25T03:10:36-07:00
is_lateral_inspection
false