Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2017, 05:08 PM
  • Section#3 C 0350 C 0349 12152017 G6883.mp4

Date
12/15/2017
W/O
0643523
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00139
PipeID
P09813
Time
9:08 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6883
Sewer Name
C JOINT OUTFALL C - UNIT 8A
City
LONG BEAH
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Routine Assessment
Project
20171214DF_JOINT_OUTFALL_C_UNIT_8A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
C 0350
Downstream MH
C 0349
Dir. of Survey
Downstream
Length Surveyed
399.3 ft.
Total Length
399.3 ft.
Structural Index
3
Structural Quick
5O3n
Structural Rating
1264
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
1267
Pipe schematic from manhole C 0350 to C 0349
MH: C 0350MH: C 0349downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 9:08 AM0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRP - Surface Reinforcement Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start208.6 ft. MGP - General Photograph399.2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.2 ft. ID - Infiltration Dripper, from 11 to 02 o'clock, within 8 inches of joint: YES399.2 ft. SRP - Surface Reinforcement Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.3 ft. MGP - General Photograph399.3 ft. MGP - General Photograph399.3 ft. MSA - Survey Abandoned - NOT ENOUGH FLOW

Observation photos (9)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    208.6 ft. - General Photograph

  • Infiltration Dripper, from 11 to 02 o'clock, within 8 inches of joint: YES

    399.2 ft. - Infiltration Dripper, from 11 to 02 o'clock, within 8 inches of joint: YES

  • General Photograph

    399.3 ft. - General Photograph

  • General Photograph

    399.3 ft. - General Photograph

Observations (18)

DistanceCodeObservation
2SSS
2SAV
399.2SRV
399.2SSS
399.2SAP
0MWL
399.2SAV
399.2ID
2SAP
208.6MGP
399.3MGP
2SRV
0AMH9:08 AM
0MWM
399.3MGP
2SRP
399.3MSANOT ENOUGH FLOW
399.2SRP

Properties (5)

custom_field_two
5
customer
LACSD
datetime
2017-12-15T09:08:02-08:00
documentation
FRANKLIN, IGNACIO, VENDRYES, PARAISO
is_lateral_inspection
false