- Date
- 12/01/2020
- W/O
- 854904
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00805
- PipeID
- P16354
- Time
- 12:38 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8319
- Sewer Name
- DISTRICT #22 MAIN TRUNK
- City
- COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- WO_854905_TV22151_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 22 0113
- Downstream MH
- 22 0112
- Dir. of Survey
- Downstream
- Length Surveyed
- 403 ft.
- Total Length
- 403 ft.
- Structural Index
- 3
- Structural Quick
- 5O3O
- Structural Rating
- 800
- O&M Index
- 2
- O&M Quick
- 2O11
- O&M Rating
- 161
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 961
Pipe schematic from manhole 22 0113 to 22 0112 Observation photos (2)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start