- Date
- 11/18/2020
- W/O
- 854910
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00659
- PipeID
- P23032
- Time
- 12:04 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8216
- Sewer Name
- LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- WO_854910_TV16078_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Square
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 16 0720
- Downstream MH
- 16 0534
- Dir. of Survey
- Upstream
- Length Surveyed
- 69.1 ft.
- Total Length
- 69 ft.
- Structural Index
- 2
- Structural Quick
- 312B
- Structural Rating
- 29
- O&M Index
- 3
- O&M Quick
- 3A00
- O&M Rating
- 36
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 65
Pipe schematic from manhole 16 0720 to 16 0534 Observation photos (5)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COAT

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

9.2 ft. - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

69.1 ft. - Survey Abandoned - COMPLETED REVERSAL