- Date
- 11/17/2020
- W/O
- 854910
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00659
- PipeID
- P13587
- Time
- 10:12 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8216
- Sewer Name
- LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- WO_854910_TV16078_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 16 0536
- Downstream MH
- 16 0535
- Dir. of Survey
- Downstream
- Length Surveyed
- 223.5 ft.
- Total Length
- 223.5 ft.
- Structural Index
- 3
- Structural Quick
- 3H2H
- Structural Rating
- 220
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 220
Pipe schematic from manhole 16 0536 to 16 0535 Observation photos (4)

2.8 ft. - General Observation - MAG COAT

2.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

149.3 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 8"