Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2020, 10:52 AM
  • 16 0555_16 0554_11162020_025738.mp4

Date
11/16/2020
W/O
854910
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00659
PipeID
P13606
Time
2:52 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8211
Sewer Name
LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
15
Purpose
Routine Assessment
Project
WO_854910_TV16078_OCT2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
16 0554
Downstream MH
16 0555
Dir. of Survey
Upstream
Length Surveyed
41.3 ft.
Total Length
41.3 ft.
Structural Index
3
Structural Quick
3828
Structural Rating
40
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole 16 0554 to 16 0555
MH: 16 0554MH: 16 0555upstream0 ft. AMH - Upstream Manhole, Survey Ends - 16 05550.1 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish13.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"38.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start38.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start38.5 ft. MGO - General Observation - MAG COAT41.3 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK41.3 ft. MWL - Water Level, 10 %of cross sectional area41.3 ft. AMH - Downstream Manhole, Survey Begins - 16 055441.3 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2.8 ft. - General Observation - MAG COAT

Observations (12)

DistanceCodeObservation
28.1TF
2.8SAP
41.3AMH16 0555
41.2MGOCONNECTION AT MH, 9 O'CLOCK
0MGOCONNECTION AT MH, 9 O'CLOCK
40.6SSS
40.6SAP
0MWL
0AMH16 0554
2.8SSS
2.8MGOMAG COAT
0MWM

Properties (6)

custom_field_three
AGGREGATE PROJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2020-11-16T02:52:18-08:00
documentation
PRO PIPE
is_lateral_inspection
false