Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 20, 2020, 09:13 AM
  • 18 0244_18 0243 _11202020_011917.mp4

Date
11/20/2020
W/O
855022
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00674
PipeID
P14072
Time
1:13 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8219
Sewer Name
EAST IMPERIAL HIGHWAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_855022_TV18005_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0243
Downstream MH
18 0244
Dir. of Survey
Upstream
Length Surveyed
50.4 ft.
Total Length
50.4 ft.
Structural Index
4
Structural Quick
4800
Structural Rating
32
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
3
Overall Quick
Overall Rating
52
Pipe schematic from manhole 18 0243 to 18 0244
MH: 18 0243MH: 18 0244upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 02440.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.9 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK43.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start48.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start50.4 ft. MWM - Water Mark, 15 %of cross sectional area50.4 ft. MWL - Water Level, 10 %of cross sectional area50.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0243

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
49.5DAGS
0MWM
0MWL
49.5FM
49.5MGOCONNECTION AT MH, 3 O'CLOCK
2DAGS
0AMH18 0243
50.4AMH18 0244
7.1FM

Properties (6)

custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-11-20T01:13:36-08:00
documentation
PRO PIPE
is_lateral_inspection
false