Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 3, 2020, 07:22 AM
  • 22 1043_22 1042 _12022020_233555.mp4

Date
12/02/2020
W/O
854909
Weather
Operator/Surveyor
B.FUGATE
Sewer ID
Z00811
PipeID
P17412
Time
11:22 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8321
Sewer Name
IRWINDALE TRUNK, SECTION 1
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_854909_TV22108_OCT2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
22 1042
Downstream MH
22 1043
Dir. of Survey
Upstream
Length Surveyed
436.5 ft.
Total Length
436.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 1042 to 22 1043
MH: 22 1042MH: 22 1043upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 1043434.3 ft. MGO - General Observation - MAG COAT436.5 ft. AMH - Downstream Manhole, Survey Begins - 22 1042436.5 ft. MWM - Water Mark, 25 %of cross sectional area436.5 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK436.5 ft. MWL - Water Level, 10 %of cross sectional area

Observations (6)

DistanceCodeObservation
0AMH22 1042
0MWM
0MGOCONNECTION AT MH, 9 O'CLOCK
436.5AMH22 1043
2.2MGOMAG COAT
0MWL

Properties (7)

additional_info
630138120220201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2020-12-02T23:22:12-08:00
documentation
PROPIPE
is_lateral_inspection
false