- Date
- 12/19/2017
- W/O
- 0674351
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00151
- PipeID
- P09910
- Time
- 4:30 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6887
- Sewer Name
- D JOINT OUTFALL D - UNIT 2A
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- 20171219MDM_JOINT_OUTFALL_D_UNIT_2A
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Upstream MH
- D 0018
- Downstream MH
- D 0016
- Dir. of Survey
- Downstream
- Length Surveyed
- 1085.9 ft.
- Total Length
- 1085.9 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole D 0018 to D 0016 Observation photos (7)

8.1 ft. - General Observation - 57" RCP-FR POLY LINE

61.5 ft. - General Observation - WHITE BULID UP FLAKING OFF PIPE

218.2 ft. - General Observation - 57" RCP-FR POLY LINER

462 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN 90% GREASE

612.5 ft. - General Observation - FR POLY LINER

856.6 ft. - General Observation - WHITE BULD UP ON PIPE

968.3 ft. - General Photograph