Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 19, 2020, 06:52 AM
  • C 0346_C 0345 _11182020_230749.mp4

Date
11/18/2020
W/O
855311
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00138
PipeID
P09809
Time
10:52 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8304
Sewer Name
JOINT OUTFALL C - UNIT 7B
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_855311_TV03115_OCT2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
15 in.
Upstream MH
C 0346
Downstream MH
C 0345
Dir. of Survey
Downstream
Length Surveyed
12.6 ft.
Total Length
12.6 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole C 0346 to C 0345
MH: C 0346MH: C 0345downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03462.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.4 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish11.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish12.6 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    12.6 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observations (10)

DistanceCodeObservation
12.6MSAVIEW OF D/S SIPHON FROM U/S MH
11.4SRV
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
11.4SAP
2.1SAP
2.1SRV
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0AMHC 0346

Properties (7)

additional_info
630075111820202
custom_field_three
AGGREGATE PROJECTING/ REINFOREMENT VISIBLE
custom_field_two
2
customer
1
datetime
2020-11-18T22:52:07-08:00
documentation
PROPIPE
is_lateral_inspection
false