Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 2, 2020, 09:12 AM
  • H 0791_H 0790A_12022020_014909.mp4

Date
12/02/2020
W/O
855744
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00942
PipeID
P23091
Time
1:12 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8258
Sewer Name
JOINT OUTFALL H - UNIT 9C
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Routine Assessment
Project
WO_855744_TV22079_OCT2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
20 in.
Width
20 in.
Upstream MH
H 0791
Downstream MH
H 0790A
Dir. of Survey
Downstream
Length Surveyed
1158.2 ft.
Total Length
1158.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2m00
O&M Rating
462
Overall Index
2
Overall Quick
Overall Rating
462
Pipe schematic from manhole H 0791 to H 0790A
MH: H 0791MH: H 0790Adownstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 07910 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start1158.2 ft. MSA - Survey Abandoned - DUE TO PIPE ALIGNMENT.1158.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0MWM
1158.2MSADUE TO PIPE ALIGNMENT.
0AMHH 0791
0MWL
1158.2DAGS
2DAGS

Properties (7)

additional_info
630069120120201
custom_field_three
ABANDONED DUE TO ALIGNMENT
custom_field_two
4
customer
1
datetime
2020-12-02T01:12:05-08:00
documentation
PRO PIPE
is_lateral_inspection
false