Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 3, 2020, 07:14 AM
  • H 0770_H 0769_12022020_233813.mp4

Date
12/02/2020
W/O
855744
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00942
PipeID
P11178
Time
11:14 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8259
Sewer Name
JOINT OUTFALL H - UNIT 9C
City
COVINA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
25
Purpose
Routine Assessment
Project
WO_855744_TV22079_OCT2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
28 in.
Width
28 in.
Upstream MH
H 0770
Downstream MH
H 0769
Dir. of Survey
Downstream
Length Surveyed
678.8 ft.
Total Length
678.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
312Z
O&M Rating
273
Overall Index
2
Overall Quick
Overall Rating
273
Pipe schematic from manhole H 0770 to H 0769
MH: H 0770MH: H 0769downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 07700 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start678.8 ft. MSA - Survey Abandoned - DUE TO DEBRIS.678.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish678.8 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMHH 0770
2DAGS
0MWL
678.8MSADUE TO DEBRIS.
0MWM
678.8DAGS
678.8DSZDEBRIS

Properties (7)

additional_info
630069120220201
custom_field_three
ABANDONED DUE TO DEBRIS
custom_field_two
4
customer
1
datetime
2020-12-02T23:14:57-08:00
documentation
PRO PIPE
is_lateral_inspection
false