Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2018, 05:03 PM
  • G 0097_A 0041_1242018_092427.mp4

Date
12/04/2018
W/O
0742380
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00334
PipeID
P08417
Time
9:03 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7869
Sewer Name
A JOINT OUTFALL A - UNIT 3C
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
09
Purpose
Routine Assessment
Project
20181204HSHO_JOINT_OUTFALL_A_UNIT_3C
Material
RCP-CTL
Shape
Square
Height
78 in.
Width
78 in.
Upstream MH
G 0097
Downstream MH
A 0041
Dir. of Survey
Downstream
Length Surveyed
485.1 ft.
Total Length
485.1 ft.
Structural Index
4
Structural Quick
5433
Structural Rating
29
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
29
Pipe schematic from manhole G 0097 to A 0041
MH: G 0097MH: A 0041downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - G 009716 ft. MGO - General Observation - 50% TO 95% MISSING TILES31.4 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES, Start62.3 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO69.3 ft. SRC - Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO107.8 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start126.2 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Finish158.2 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES, Finish158.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start350 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES401 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish425.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start485.1 ft. AMH - Downstream Manhole, Survey Ends - A 0041485.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (7)

  • General Observation - 50% TO 95% MISSING TILES

    16 ft. - General Observation - 50% TO 95% MISSING TILES

  • Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES, Start

    31.4 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO

    62.3 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO

    69.3 ft. - Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start

    107.8 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    158.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    425.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
401SAV
350SRV
425.2SAV
126.2SRV
16MGO50% TO 95% MISSING TILES
485.1AMHA 0041
0MWM
69.3SRC
158.5SAV
0MWL
62.3SRV
31.4SAV
107.8SRV
485.1SAV
0AMHG 0097
158.2SAV

Properties (6)

custom_field_three
REBAR AND VISIBLE AGGREGATE
custom_field_two
2
customer
LACSD
datetime
2018-12-04T09:03:21-08:00
documentation
OBREGON, YOUNG, CASTILLO
is_lateral_inspection
false