- Date
- 08/10/2018
- W/O
- 0722651
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00074
- PipeID
- P08568
- Time
- 8:53 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7782
- Sewer Name
- B JOINT OUTFALL B - UNIT 1C
- City
- PARAMOUNT
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- 20180810SHO_JOINT_OUTFALL_B_UNIT_1C
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 72 in.
- Upstream MH
- B 0096B
- Downstream MH
- B 0096A
- Dir. of Survey
- Downstream
- Length Surveyed
- 30.2 ft.
- Total Length
- 30.2 ft.
- Structural Index
- 4
- Structural Quick
- 5231
- Structural Rating
- 13
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole B 0096B to B 0096A Observation photos (4)

23.4 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO, Start

23.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

29.6 ft. - Surface Reinforcement Visible, from 09 to 10 o'clock, within 8 inches of joint: YES

30.2 ft. - Downstream Manhole, Survey Ends - MH 96A